| Model |
CS
08
|
CS
12
|
CS
21
|
CS
31
|
|
| Capacity | |||||
| Thermal capacity |
KW
|
850
|
1'250
|
2'100
|
3'125
|
| Throughput volume |
kg/h
|
200
|
300
|
500
|
750
|
| Max. daily charging time |
h
|
24
|
24
|
24
|
24
|
| Max. daily capacity |
to/day
|
4.8
|
7.2
|
12
|
16
|
| Combustion | |||||
| Combustion chamber volume |
m3
|
7.5
|
12
|
20
|
28
|
| Burner capacity |
kW
|
400
|
500
|
750
|
1'000
|
|
¦
|
|||||
| Incineration temperature |
° C
|
600 - 1'200
|
600 - 1'200
|
600 - 1'200
|
600 - 1'200
|
| Post-combustion | |||||
| Post-combustion chamber volume |
m3
|
10
|
16
|
27
|
34
|
| Burner capacity |
MW
|
500 + 1'200
|
600 + 1'700
|
700 + 3'000
|
800 + 4'500
|
| Post-combustion temperature |
°
C
|
1'100
|
1'100
|
1'100
|
1'100
|
| Residence time |
sec
|
2
|
2
|
2
|
2
|
| Flue gas cleaning | |||||
| Cleaning system |
dry adsorption /
|
Sorbalit
|
|||
| Filter area |
m2
|
70
|
100
|
168
|
250
|
| Max. filter speed |
m/min.
|
0.9
|
0.9
|
0.9
|
0.9
|
| Max. gas temperature |
° C
|
240
|
240
|
240
|
240
|
| Consumption | (Deatails are based on experience values and depend very much on waste properties) | ||||
| Fuel heating oil light |
kg/h
|
16
|
22
|
32
|
47
|
| Alternative: natural gas (G20) |
Nm3/h
|
19
|
26
|
39
|
57
|
|
¦
|
|||||
| Adsorbent / Sorbalit |
kg/h
|
9
|
12
|
20
|
30
|