Flue gas purification
 
WET

wet 2   wet 1
Flue gas cleaning is determined by the waste to be removed and the local regulations!
A two or multi-stage wet washer is normally connected in serial mode for widely differing or unknown waste materials or if high levels of pollutants are present. Chlorine and hydrogen fluorides, in addition to heavy metals, are mainly washed out in the first stage with an acidic solution (pH 1-3) and sulphur dioxide in the second stage with a basic solution (pH 7-8).
The pollutants present in form of dust, salts and heavy metals and washed out by the chemical reaction are fed to a corresponding sewage treatment process and eliminated in concentrated form.
wet 3

CONFIGURATION
FLUE GAS EMISSION
ADVANTAGE
incinerator
post-combustion chamber
waste heat boiler
quencher
wet scrubber
exhaust fan
stack
Dust
SO2
HCI
HF
heavy metals
dioxins
mg/Nm3
mg/Nm3
mg/Nm3
mg/Nm3
mg/Nm3
ng/Nm3
20
50
10
2
1
0.5
low flue gas emission

without filter dust
»» see flue gas purification systems - overview  